CONSTRUCTION:
1. Electrical conductor is copper.
2. Insulation is two-layer, made of low-pressure polyethylene.
3. Bedding is made of non-woven fabric tapes.
4. Armor is made of galvanized (B) or stainless steel (Bk) tape
The cables are designed to supply electric power to motors of oil production units at the rated AC voltage of 3.3 kV with a frequency of up to 70 Hz.
The cables are used in wells at the average temperature of pumped fluid and with the average content of corrosive substances.
Cables are available in flat (P) and round (K) designs.
|
Cable type |
Number and nominal conductor section, mm |
Outer cable dimensions, mm, not more |
Estimated cable weight 1 km, kg |
|
KPBK-90 KPBkK-90 Un=3,3kV |
3×10 |
24,7 |
799 |
|
3×13,3 |
26,2 |
914 |
|
|
3×16 |
27,1 |
1007 |
|
|
3×21,15 |
28,6 |
1185 |
|
|
3×25 |
29,4 |
1328 |
|
|
3×35 |
31,8 |
1622 |
|
|
3×50 |
34,0 |
2015 |