| LME.Copper | 14157.00 |
| LME.Aluminium | 3266.00 |
| Currency | Value | Edit | |
| USD CB RF | 85.1645 | 0.1509 | |
| EUR CB RF | 98.7312 | 0.3960 |
CONSTRUCTION:
1. Electrical conductor is copper.
2. The first insulation layer is made of radiationmodified high-density polyethylene.
3. The second insulation layer is propylene-ethylene block copolymer.
4. Bedding is made of non-woven fabric tapes.
5. Armor is made of galvanized (B) or stainless steel (Bk) tape.
The cables are designed to supply electric power to motors of oil production units at the rated AC voltage of 3.3; 4 and 5 kV.
The cables are used in wells at the average temperature of pumped fluid and with the average content of corrosive substances.
Cables are available in flat (P) and round (K) designs.
| Cable type Un=3,3 kV |
Number and nominal conductor section, mm |
Outer cable dimensions, mm, not more |
Cable type Un= 4 kV |
Outer cable dimensions, mm, not more |
Cable type Un= 5 kV |
Outer cable dimensions, mm, not more |
|
KPvPpBK-120, KPvPpBkK-120 |
3×10 |
24,7 |
KPvPpBK-120, KPvPpBkK-120 |
25,6 |
KPvPpBK-120, KPvPpBkK-120 |
26,4 |
|
3×13,3 |
25,8 |
26,6 |
27,5 |
|||
|
3×16 |
26,6 |
27,5 |
28,4 |
|||
|
3×21,15 |
28,1 |
29,0 |
29,9 |
|||
|
3×25 |
29,0 |
29,9 |
30,7 |
|||
|
3×35 |
31,4 |
32,2 |
33,1 |
|||
|
3×50 |
33,5 |
34,4 |
35,3 |
|
Uн, кВ |
Cable type |
Number and nominal conductor section, mm |
||||||
|
3×10 |
3×13,3 |
3×16 |
3×21,15 |
3×25 |
3×35 |
3×50 |
||
|
Estimated cable weight 1 km, kg |
||||||||
|
3,3 |
KPvPpBK-120, KPvPpBkK-120 |
797 |
912 |
1006 |
1183 |
1327 |
1620 |
2013 |
|
4 |
813 |
928 |
1022 |
1200 |
1344 |
1639 |
2032 |
|
|
5 |
843 |
959 |
1055 |
1233 |
1378 |
1674 |
2072 |
|