KPvPpBK-130, KPvPpBkK-130

Download catalogue
KPvPpBK-130, KPvPpBkK-130
CONSTRUCTION: 1. Electrical conductor is copper. 2. The first insulation layer is made of radiationmodified high-density polyethylene. 3. The second insulation layer is propylene-ethylene block copolymer. 4. Bedding is made of non-woven fabric tapes. 5. Armor is made of galvanized (B) or stainless steel (Bk) tape.
To buy products "KPvPpBK-130, KPvPpBkK-130" from the manufacturing plant INKATEH LLC and request a price list with the price, call +7 (846) 226-51-73 or fill out an make a request.
Make a request

The cables are designed to supply electric power to motors of oil production units at the rated AC voltage of 3.3; 4 and 5 kV. 

The cables are used in wells at the average temperature of pumped fluid and with the average content of corrosive substances. 

Cables are available in flat (P) and round (K) designs.

Maximum heating temperature of conductor 130 °С.
-Collapse table +Expand table «»

Cable type Un=3,3 kV

Number of conductors and nominal section, mm

Outer cable dimension, mm, not more

Cable type Un=4 kV

Outer cable dimension, mm, not more

Cable type Un=5 kV

Outer cable dimension, mm, not more

KPvPpBK-130, KPvPpBkK-130

3×10

24,7

KPvPpBK-130, KPvPpBkK-130

25,6

KPvPpBK-130, KPvPpBkK-130

26,4

3×13,3

25,8

26,6

27,5

3×16

26,6

27,5

28,4

3×21,15

28,1

29,0

29,9

3×25

29,0

29,9

30,7

3×35

31,4

32,2

33,1

3×50

33,5

34,4

35,3

-Collapse table +Expand table «»

Uн, кВ

Cable type 

Number of conductors and nominal section, mm

3×10

3×13,3

3×16

3×21,15

3×25

3×35

3×50

Estimated cable weight 1 km, kg

3,3

KPvPpBK-130, KPvPpBkK-130

797

912

1006

1183

1327

1620

2013

4

813

928

1022

1200

1344

1639

2032

5

843

959

1055

1233

1378

1674

2072

To buy products "KPvPpBK-130, KPvPpBkK-130" from the manufacturing plant INKATEH LLC and request a price list with the price, call +7 (846) 226-51-73 or fill out an make a request.
Make a request

Request call back
* — required fields