KGVEV, KGVEVng(A), KGVEVng(A)-LS at 0,66 and 1 kV

Download catalogue
KGVEV, KGVEVng(A), KGVEVng(A)-LS at 0,66 and 1 kV

CONSTRUCTION: 

1. Electric conductor – copper multiwire, round shape, flexibility 5 grade acc.to GOST 22483. 2

. Insulation from PVC compound. Core – insulated two, three, four and five cable conductors twisted between each other. Inner сore interval from insulated conductors filled with harness, pressed from polyvinylchloride compound. Multiwire cables have equal section conductors. Four conductor cables with section 25 mm2 and more may have one conductor smaller section (neutral or ground conductor). 

3. Inner sheath from PVC compound. 

4. Shield – copper band, laid above inner sheath. 

5. Outer sheath – from PVC compound. 


For cable KGVEVng(A) – inner and outer sheath from low fire performance PVC compound. 

For cable KGVEVng(A)-LS – inner and outer sheath insulation from low fire hazard PVC compound.

To buy products "KGVEV, KGVEVng(A), KGVEVng(A)-LS at 0,66 and 1 kV" from the manufacturing plant INKATEH LLC and request a price list with the price, call +7 (846) 226-51-73 or fill out an make a request.
Make a request
Flexible power cables with copper conductors, insulation and sheath from PVC compound shielded KGVEV, KGVEVng(A), KGVEVng(A)-LS used for transmission and distribution of electric energy in stationary units as well as for fixed assembly of power supply circuits for machinery and equipment at nominal alternating voltage 0,66 and 1 kV, nominal frequency 50 Hz or at direct voltage up to 1 and 1,5 kV.
It`s not recommended to lay cables in ground (trenches) and on the open air without additional solar protection. Cables designed for general use application.

Cables can be laid without limitation of level differences on the routing, including vertical areas.
Cables could be used for direct voltage electric networks, not exceeding 2,4U0.
Cables KGVEV are flame-retardant at single laying.
Cables KGVEVng(A) and KGVEVng(A)-LS used for bunched laying in cable structures and inner (closed) electric units, for wiring in apartments and public buildings.
Fire hazard grade for cable KGVEV acc.to GOST 31565: O.1.8.2.5.4
Fire hazard grade for cable KGVEVng(A) acc. to GOST 31565: P16.8.2.5.4.
Fire hazard grade for cable KGVEVng(A)-LS acc. to GOST 31565: P16.8.2.2.2.
-Collapse table +Expand table «»

KGVEV, KGVEVng(A), KGVEVng(A)-LS

Number and nominal conductor section, mm²

Nominal outer cable diameter, mm

Estimated cable weight, kg/km

0,66 kV

1 kV

0,66 kV

1 kV

1х6

9,7

10,7

155

179

1х10

11,0

11,6

215

230

1х16

12,2

12,8

290

306

1х25

13,9

14,5

402

421

1х35

15,4

16,0

528

549

1х50

17,2

17,8

695

718

1х70

*

19,7

*

952

1х95

*

21,8

*

1209

1х120

*

23,4

*

1452

1х150

*

26,3

*

1882

1х185

*

28,2

*

2201

1х240

*

31,7

*

2842

1х300

*

33,8

*

3431

2х6 (N)

14,8

16,0

347

390

2х10(N)

17,4

17,8

503

519

2х16 (N)

19,8

20,2

695

714

2х25(N)

23,2

23,6

992

1013

2х35(N)

26,5

27,1

1369

1405

2х50(N)

30,1

30,7

1816

1858

2х70(N)

*

35,3

*

2529

2х95 (N)

*

39,5

*

3226

2х120(N)

*

43,1

*

3931

2х150(N)

*

48,3

*

4951

2х185(N)

*

52,1

*

5808

2х240(N)

*

59,1

*

7539

3х6

15,5

16,7

413

460

3х10

18,3

18,7

610

626

3х16

20,8

21,3

861

879

3х25

24,8

25,4

1295

1329

3х35

28,0

28,7

1732

1769

3х50

32,3

32,9

2347

2388

3х70

*

37,4

*

3232

3х95

*

41,9

*

4144

3х120

*

46,2

*

5120

3х150

*

51,3

*

6408

3х185

*

56,2

*

7634

3х240

*

62,9

*

9811

4х6 (N)

16,6

18,1

504

554

4х10(N)

19,8

20,2

760

765

4х16 (N)

22,7

23,1

1080

1090

4х25(N)

27,1

27,7

1619

1651

4х35 (N)

30,7

31,8

2189

2237

4х50 (N)

35,8

36,5

3004

3031

4х70 (N)

*

41,1

*

4084

4х95(N)

*

46,9

*

5344

4х120 (N)

*

50,8

*

6487

4х150(N)

*

57,4

*

8248

4х185 (N)

*

62,0

*

9714

4х240 (N)

*

70,8

*

12725

5х6 (N, PE)

17,9

19,6

605

665

5х10 (N, PE)

21,4

22,0

921

945

5х16 (N, PE)

24,9

25,6

1327

1342

5х25 (N, PE)

29,6

30,3

1988

1997

5х35 (N, PE)

34,4

35,2

2757

2800

5х50 (N, PE)

39,3

40,0

3715

3790

5х70 (N, PE)

*

46,0

*

5093

5х95 (N, PE)

*

51,6

*

6546

5х120 (N, PE)

*

56,8

*

8077

5х150 (N, PE)

*

63,2

*

10160

5х185 (N, PE)

*

69,4

*

12113

5х240 (N, PE)

*

78,1

*

15723

3х70+1х35(N)

*

39,7

*

2305

3х95+1х50 (N)

*

45,3

*

3018

3х120+1х70 (N)

*

49,0

*

3720

3х150+1х70 (N)

*

53,3

*

4232

3х185+1х95 (N)

*

59,8

*

5409

3х240+1х120 (N)

*

67,9

*

6942

To buy products "KGVEV, KGVEVng(A), KGVEVng(A)-LS at 0,66 and 1 kV" from the manufacturing plant INKATEH LLC and request a price list with the price, call +7 (846) 226-51-73 or fill out an make a request.
Make a request

Type of climatic category acc. to GOST 15150: UXL, placement category 1-5 Range of operating temperatures: from -500C up to +500C. 

Smoke emission at burning and smouldering of cables KGVEVng(A)-LS not decrease light transmission in test chamber more than 50%. 

Value of equivalent toxicity index of burning cables KGVEVng(A)-LS not more 40 g/m3 Relative atmosphere humidity at temperature up to +350C: up to 98% Cable laying and assembly without preheating at temperature not less: -150C. 

Admissible force at cable tension on the tray should not exceed 50 N/mm2 Cable conductor continuous heating temperature at work: +700C. 

Maximum allowable temperature of conductors heating at short current circuits: +1600C Short circuit duration should not exceed 5 sec. 

Admissible heating of cable conductors in emergency state: not more +900C. 

Operating period of cables in overload period should not exceed 8 hours per day and not more 1000 hours per life period. 

Maximum temperature of electric cable conductors without fire outbreak at short circuit – not more 3500C. 

Minimum bending radius at laying not less: 

- For single wires 10 diameters of cable 

- For multiwires 7,5 diameters of cable 

Life period: 30 years, according to stated transportation, storage, laying (assembly) and operation terms. 

Guaranteed operating period: 5 years from the date of putting cable into operation, but not later 6 months from the production date.  

To buy products "KGVEV, KGVEVng(A), KGVEVng(A)-LS at 0,66 and 1 kV" from the manufacturing plant INKATEH LLC and request a price list with the price, call +7 (846) 226-51-73 or fill out an make a request.
Make a request

Request call back
* — required fields