VBSHv, VBSHvng(A) at 0,66 and 1 kV

Download catalogue
VBSHv, VBSHvng(A) at 0,66 and 1 kV

CONSTRUCTION: 

1. Electric conductor – copper single or multiwire, round or sectoral shape, according to 1 or 2 grade, GOST 22483. 

2. Insulation from polyvinylchloride compound. Core – insulated conductors twisted between each other and fastened by polypropylene thread (for sectoral conductors). Insulated conductors of multiwire cables have distinct colouring. Neutral conductor insulation has blue colouring. Grounding conductor insulation has two-colouring (green-yellow). Inner сore interval from insulated conductors filled with harness, pressed from polyvinylchloride compound. 

3. Inner sheath from polyvinylchloride compound. 

4. Armour protection from two steel galvanized bands. 5. Protective hose from polyvinylchloride compound. 


For cable VBSHvng(A) inner and outer sheath from low-flammable polyvinylchloride compound.

To buy products "VBSHv, VBSHvng(A) at 0,66 and 1 kV" from the manufacturing plant INKATEH LLC and request a price list with the price, call +7 (846) 226-51-73 or fill out an make a request.
Make a request

Cable grades VBSHv and VBSHvng(A) used for transmission and distribution of electric energy in stationary units at nominal voltage 0,66 and 1 kV, nominal frequency 50 Hz or at direct voltage up to 1 and 1,5 kV. Electric networks with ground or insulated neutral in which operating time of single-phase short circuit to ground not exceed 8 hours, overall operating time of single-phase short circuit to ground not exceed 125 hours per year. It`s allowed to lay cables in ground (trenches). 

Cables can be laid without limitation of level differences on the routing, including vertical areas.  

Maximum network voltage for operating cables Um equals to 1,2U. 

Cables could be used for direct voltage electric networks, not exceeding 2,4U0. 

Cable grades VBSHv used for single cable lines laying in structures and outer (open) electric units (cable tray system, galleries) Bunched laying of such cables necessary to use fireproof equipment. 

Cable grades VBSHvng(A) used for bunched laying in cable structures and outer (open) electric units (cable tray system, galleries). 

Fire hazard grade for cable grade VBSHv acc.to GOST 31565: O.1.8.2.5.4 

Fire hazard grade for cable grade VBSHvng(A) acc. to GOST 31565: P16.8.2.5.4.

-Collapse table +Expand table «»

VBSHv, VBSHvng(A)

Number and nominal conductor section, mm2²

Nominal outer cable diameter, mm

Estimated cable weight, kg/km

0,66 kV

1 kV

0,66 kV

1 kV

2х6, ок, (N)

14,8

16,0

358

398

2х10, ок, (N)

17,1

17,5

498

513

2х16, ок, (N)

18,9

19,3

651

673

2х25, ок, (N)

22,0

22,4

909

933

2х35, ок, (N)

24,3

24,7

1161

1186

2х50, ок, (N)

27,2

27,6

1485

1512

3х6, ок

15,4

16,7

425

472

3х10, ок

17,9

18,4

607

624

3х16, ок

19,9

20,3

813

837

3х25, ок

23,1

23,5

1157

1184

3х35, ок

25,6

26,0

1495

1524

3х50, ок

28,7

29,2

1933

1964

4х6, ок, (N)

16,4

17,9

506

561

4х10, ок, (N)

19,3

19,8

734

754

4х16, ок, (N)

21,5

22,0

997

1032

4х25, ок, (N)

25,5

26,0

1458

1496

4х35, ок, (N)

27,9

28,4

1867

1917

4х50, ок, (N)

31,4

31,8

2428

2480

5х6, ок, (N, PE)

17,6

19,2

602

666

5х10, ок, (N, PE)

20,8

21,4

888

911

5х16, ок, (N, PE)

23,3

24,2

1209

1268

5х25, ок, (N, PE)

27,7

28,3

1781

1826

5х35, ок, (N, PE)

30,4

30,9

2298

2331

5х50, ок, (N, PE)

35,1

35,6

3054

3091

3х25ок+1х16ок, (N)

25,3

25,4

1773

1390

3х35ок+1х16ок, (N)

27,0

27,1

2077

1693

3х50ок+1х25ок, (N)

30,4

30,5

3154

2218

2х16, мк, (N)

19,4

19,8

678

684

2х25, мк, (N)

22,6

23

951

957

2х35, мк, (N)

25,0

25,4

1206

1213

2х50, мк, (N)

28,8

29,2

1601

1608

3х16, мк

20,4

20,79

832

856

3х25, мк

24,2

24,63

1212

1240

3х35, мк

26,4

26,78

1531

1561

3х50, мк

30,4

30,9

2055

2087

4х16, мк, (N)

22,0

22,506

1031

1054

4х25, мк, (N)

26,3

26,762

1512

1538

4х35, мк, (N)

28,7

29,172

1932

1960

4х50, мк, (N)

33,7

34,6

2633

2696

5х16, мк, (N, PE)

24,3

24,82

1268

1295

5х25, мк, (N, PE)

28,6

29,14

1844

1876

5х35, мк, (N, PE)

31,3

31,84

2366

2400

5х50, мк, (N, PE)

37,2

37,8

3169

3296

3х50, мс

28,3

28,2

1945

1971

3х70, мс

*

31,1

*

2599

3х95, мс

*

35,5

*

3469

3х120, мс

*

38,0

*

4201

3х150, мс

*

41,3

*

5138

3х185, мс

*

45,6

*

6292

3х240, мс

*

51,1

*

8230

4х50, мс, (N)

31,5

31,4

2508

2534

4х70, мс, (N)

*

35,5

*

3427

4х95, мс, (N)

*

39,6

*

4520

4х120, мс, (N)

*

42,6

*

5487

4х150, мс, (N)

*

47,2

*

6809

4х185, мс, (N)

*

51,8

*

8539

4х240, мс, (N)

*

58,1

*

10854

5х50, мс, (N, PE)

36,2

35,3

3162

3179

5х70, мс, (N, PE)

*

39,0

*

4230

5х95, мс, (N, PE)

*

44,1

*

5594

5х120, мс, (N, PE)

*

47,8

*

6838

5х150, мс, (N, PE)

*

52,7

*

8668

5х185, мс, (N, PE)

*

57,9

*

10559

5х240, мс, (N, PE)

*

64,2

*

13335

3х70мс+1х35ок, (N)

*

33,9

*

3015

3х95мс+1х50мс, (N)

*

38,3

*

4036

3х120мс+1х70мс, (N)

*

41,3

*

4966

3х150мс+1х70мс, (N)

*

45,2

*

5974

3х185мс+1х95мс, (N)

*

49,2

*

7316

3х240мс+1х120мс, (N)

*

55,9

*

9615

2х50, мс, (N)

*

24,9

*

1433

2х70, мс, (N)

*

26,9

*

1853

2х95, мс, (N)

*

29,8

*

2434

2х120, мс, (N)

*

31,8

*

2906

2х150, мс, (N)

*

34,9

*

3584

2х185, мс, (N)

*

37,6

*

4317

2х240, мс, (N)

*

41,4

*

5443

To buy products "VBSHv, VBSHvng(A) at 0,66 and 1 kV" from the manufacturing plant INKATEH LLC and request a price list with the price, call +7 (846) 226-51-73 or fill out an make a request.
Make a request

Type of climatic category acc. to GOST 15150: UXL, placement category 1-5. 

Cable grades VBSHv are flame retardant at single laying. 

Cable grades VBSHvng(A) are flame retardant at bunched laying. 

Range of operating temperatures: from -500C up to +500C. 

Relative atmosphere humidity at temperature up to +350C: up to 98% Cable laying and assembly without preheating at temperature not less: -150C. 

Admissible force at cable tension on the tray should not exceed 50 N/mm2 Cable conductor continuous heating temperature at work: +700C. 

Maximum allowable temperature of conductors heating at short current circuits: +1600C Short circuit duration should not exceed 5 sec. 

Admissible heating of cable conductors in emergency state: not more +900C. 

Operating period of cables in overload period should not exceed 8 hours per day and not more 1000 hours per life period. 

Maximum temperature of electric cable conductors without fire outbreak at short circuit – not more 3500C. 

Minimum bending radius at laying not less: 

- For single wires 10 diameters of cable 

- For bending wires 7,5 diameters of cable 

Life period: 30 years, according to stated transportation, storage, laying (assembly) and operation terms. 

Guaranteed operating period: 5 years from the date of putting cable into operation, but not later 6 months from the production date.

To buy products "VBSHv, VBSHvng(A) at 0,66 and 1 kV" from the manufacturing plant INKATEH LLC and request a price list with the price, call +7 (846) 226-51-73 or fill out an make a request.
Make a request

Request call back
* — required fields