VVG-XL, VVGng(A)-XL for 0,66 and 1kV

Download catalogue
VVG-XL, VVGng(A)-XL for 0,66 and 1kV

CONSTRUCTION: 

1. Electric conductor – copper single or multiwire, round or sectoral shape, according to 1 or 2 grade, GOST 22483. 

2. Insulation from polyvinylchloride compound with low glass transition temperature. Core – insulated conductors twisted between each other and fastened by polypropylene thread (for sectoral conductors). Insulated conductors of multiwire cables have distinct colouring. Neutral conductor insulation has blue colouring. Grounding conductor insulation has twocolouring (green-yellow). Inner сore interval from insulated conductors filled with harness, pressed from polyvinylchloride compound. 

3. Inner sheath from polyvinylchloride compound with low glass transition temperature. 

4. Outer sheath from polyvinylchloride compound with low glass transition temperature. 

For cable VVGng(A)-XL – inner and outer sheath from low performance PVC compound with low glass transition temperature. 

To buy products "VVG-XL, VVGng(A)-XL for 0,66 and 1kV" from the manufacturing plant INKATEH LLC and request a price list with the price, call +7 (846) 226-51-73 or fill out an make a request.
Make a request

Electric networks with ground or insulated neutral in which operating time of single-phase short circuit to ground not exceed 8 hours, overall operating time of single-phase short circuit to ground not exceed 125 hours per year. 

Cables can be laid without limitation of level differences on the routing, including vertical areas. 

Maximum network voltage for operating cables Um equals to 1,2U. 

Cables could be used for direct voltage electric networks, not exceeding 2,4U0. 

Cables VVG-XL used for single cable lines laying in structures and outer (open) electric units (cable tray system, galleries). 

Bunched laying of such cables necessary to use fireproof equipment. 

Cables VVGng(A)-XL used for bunched laying in cable structures and outer (open) electric units (cable tray system, galleries). 

Fire hazard grade of cables VVG-XL acc.to GOST 31565: O.1.8.2.5.4 

Fire hazard grade of cables VVGng(A)-XL acc.to GOST 31565: P1b.8.2.5.4.

-Collapse table +Expand table «»

VVG-XL, VVGng(A)-XL

Number and nominal conductor section, mm²

Nominal outer cable diameter, mm

Estimated cable weight, kg/km

0,66 kV

1 kV

0,66 kV

1 kV

1х6, ок

6,9

7,5

96

106

1х10, ок

8,1

8,3

145

148

1х16, ок

9,2

9,4

208

212

1х25, ок

10,7

10,9

305

310

1х35, ок

11,7

11,9

399

404

1х50, ок

13,1

13,3

525

530

2х6, ок, (N)

11,8

13,0

245

278

2х10, ок, (N)

14,1

14,5

372

385

2х16, ок, (N)

17,9

18,3

598

620

2х25, ок, (N)

21,0

21,4

861

886

2х35, ок, (N)

22,9

23,3

1098

1125

2х50, ок, (N)

26,0

26,4

1446

1475

3х6, ок

12,4

13,7

302

339

3х10, ок

14,9

15,4

466

481

3х16, ок

18,9

19,3

745

769

3х25, ок

22,1

22,5

1094

1115

3х35, ок

24,4

24,8

1423

1446

3х50, ок

27,5

28,0

1865

1891

4х6, ок, (N)

13,4

14,9

376

422

4х10, ок, (N)

16,3

16,8

587

605

4х16, ок, (N)

20,5

21,0

919

952

4х25, ок, (N)

24,3

24,8

1377

1403

4х35, ок, (N)

26,7

27,2

1795

1823

4х50, ок, (N)

30,2

30,6

2357

2388

5х6, ок, (N, PE)

14,6

16,2

468

524

5х10, ок, (N, PE)

17,8

18,4

739

761

5х16, ок, (N, PE)

22,3

22,8

1121

1159

5х25, ок, (N, PE)

26,5

27,1

1676

1721

5х35, ок, (N, PE)

29,2

29,7

2191

2223

5х50, ок, (N, PE)

33,5

34,4

2926

2996

3х25ок+1х16ок, (N)

24,1

24,6

1304

1329

3х35ок+1х16ок, (N)

25,8

26,3

1606

1632

3х50ок+1х25ок, (N)

29,2

29,6

2131

2160

1х16, мк

7,5

10,2

225

230

1х25, мк

8,3

11,8

329

334

1х35, мк

9,4

12,8

424

429

1х50, мк

10,9

14,7

574

580

1х70, мк

*

15,8

*

762

1х95, мк

*

17,9

*

1025

1х120, мк

*

19,6

*

1252

1х150, мк

*

21,5

*

1530

1х185, мк

*

23,4

*

1897

1х240, мк

*

27,2

*

2483

1х300, мк

*

29,7

*

3060

2х16, мк, (N)

18,4

18,8

615

530

2х25, мк, (N)

21,6

22,0

893

747

2х35, мк, (N)

23,6

24,4

1132

945

2х50, мк, (N)

27,8

28,2

1568

1271

3х16, мк

19,4

19,8

763

788

3х25, мк

22,8

23,2

1129

1151

3х35, мк

25,4

25,8

1472

1496

3х50, мк

29,4

29,9

2005

2034

4х16, мк, (N)

21,0

21,5

952

975

4х25, мк, (N)

25,3

25,8

1431

1458

4х35, мк, (N)

27,7

28,2

1852

1881

4х50, мк, (N)

32,7

33,2

2556

2603

5х16, мк, (N, PE)

22,9

23,4

1158

1184

5х25, мк, (N, PE)

27,6

28,1

1753

1784

5х35, мк, (N, PE)

30,3

30,8

2274

2308

5х50, мк, (N, PE)

36,2

36,8

3182

3222

3х50, мс

24,8

25,0

1680

1699

3х70, мс

*

27,9

*

2298

3х95, мс

*

31,5

*

3075

3х120, мс

*

34,4

*

3810

3х150, мс

*

37,7

*

4711

3х185, мс

*

41,2

*

5760

3х240, мс

*

46,4

*

7406

4х50, мс, (N)

28,0

28,2

2204

2229

4х70, мс, (N)

*

31,5

*

3034

4х95, мс, (N)

*

36,0

*

4112

4х120, мс, (N)

*

39,0

*

5047

4х150, мс, (N)

*

42,8

*

6258

4х185, мс, (N)

*

48,0

*

7796

4х240, мс, (N)

*

53,6

*

9939

5х50, мс, (N, PE)

31,1

31,3

2774

2789

5х70, мс, (N, PE)

*

35,4

*

3830

5х95, мс, (N, PE)

*

40,1

*

5115

5х120, мс, (N, PE)

*

43,4

*

6280

5х150, мс, (N, PE)

*

48,9

*

7911

5х185, мс, (N, PE)

*

53,4

*

9647

5х240, мс, (N, PE)

*

60,0

*

12376

3х70мс+1х35ок, (N)

*

30,1

*

2379

3х95мс+1х50мс, (N)

*

34,5

*

3239

3х120мс+1х70мс, (N)

*

37,4

*

3961

3х150мс+1х70мс, (N)

*

40,6

*

4869

3х185мс+1х95мс, (N)

*

45,0

*

5987

3х240мс+1х120мс, (N)

*

50,2

*

7718

2х50, мс, (N)

*

21,5

*

1178

2х70, мс, (N)

*

23,5

*

1575

2х95, мс, (N)

*

26,8

*

2147

2х120, мс, (N)

*

28,8

*

2598

2х150, мс, (N)

*

31,1

*

3199

2х185, мс, (N)

*

33,8

*

3898

2х240, мс, (N)

*

38,0

*

5012

To buy products "VVG-XL, VVGng(A)-XL for 0,66 and 1kV" from the manufacturing plant INKATEH LLC and request a price list with the price, call +7 (846) 226-51-73 or fill out an make a request.
Make a request

Type of climatic category acc. to GOST 15150: XL, placement category 1-5. 

Cable VVG-XL are flame retardant at single laying. 

Cables VVGng(A)-XL are flame retardant at bunched laying. 

Range of operating temperatures: from -60 0C up to +500C. 

Relative atmosphere humidity at temperature up to +350C: up to 98% Cable laying and assembly without preheating at temperature not less: -25 0C. 

Admissible force at cable tension on the tray should not exceed 50 N/mm2 Cable conductor continuous heating temperature at work: +700C. 

Maximum allowable temperature of conductors heating at short current circuits: +1600C Short circuit duration should not exceed 5 sec. 

Admissible heating of cable conductors in emergency state: not more +900C. 

Operating period of cables in overload period should not exceed 8 hours per day and not more 1000 hours per life period. 

Maximum temperature of electric cable conductors without fire outbreak at short circuit – not more 3500C.

To buy products "VVG-XL, VVGng(A)-XL for 0,66 and 1kV" from the manufacturing plant INKATEH LLC and request a price list with the price, call +7 (846) 226-51-73 or fill out an make a request.
Make a request

Request call back
* — required fields