CONSTRUCTION:
1. Electric conductor – copper single or multiwire, round or sectoral shape, according to 1 or 2 grade, GOST 22483.
2. Insulation from low fire hazard polyvinylchloride compound for cables in “XL” application from low fire hazard PVC compound with low glass transition temperature.
3. Inner sheath from low fire hazard polyvinylchloride compound, for cables in “XL” application from low fire hazard PVC compound with low glass transition temperature. Inner sheath laid with spaces filling between insulated conductors.
4. Outer sheath from low fire hazard polyvinylchloride compound, for cables in “XL” application from low fire hazard PVC compound with low glass transition temperature, for cables with “m” index – outer sheath resistant to lubricants and diesel fuel, cables with “UF” index – outer sheath ultraviolet resistant.
Power cables with copper conductors, insulation and sheath from polyvinylchloride compound, low smoke and gas emissions flame-retardant, resistant to lubricants, diesel fuel and ultraviolet rays, cold-resistant grades VVGng(A)-LS-XLm(UF), VVGng(A)-LS-XL, VVGng(A)-LSm(UF) used for transmission and distribution of electric energy in stationary units at nominal alternating voltage 0,66 and 1 kV, nominal frequency 50 Hz or at direct voltage up to 1 and 1,5 kV.
Electric networks with ground or insulated neutral in which operating time of single-phase short circuit to ground not exceed 8 hours, overall operating time of single-phase short circuit to ground not exceed 125 hours per year.
Cables can be laid without limitation of level differences on the routing, including vertical areas.
Maximum network voltage for operating cables Um equals to 1,2U.
Cables could be used for operation at direct voltage of electric networks, not exceeding 2,4U0.
Cables used for bunched laying including hot loading volume in cable structures and outer (open) electric units in case of mechanical damages and absence of tension force during operating procedures.
Cables with “m” index lubricants and fuel diesel resistant.
Cables with “UF” index resistant to ultraviolet rays, can be laid outdoor without solar protection.
Cables with “XL” index used for extreme weather conditions, lowest temperature up to -600C.
Fire hazard grade acc.to GOST 31565: P1b.8.2.2.2.
|
VVGng(A)-LS-XLm(UF), VVGng(A)-LS-XL, VVGng(A)-LSm(UF) for 0,66 and 1 kV |
||||
|
Number and nominal conductor section, mm² |
Nominal outer cable diameter, mm |
Estimated cable weight, kg/km |
||
|
0,66 kV |
1 kV |
0,66 kV |
1 kV |
|
|
1х6, ок |
6,9 |
7,5 |
101 |
112 |
|
1х10, ок |
8,1 |
8,3 |
151 |
155 |
|
1х16, ок |
9,2 |
9,4 |
215 |
220 |
|
1х25, ок |
10,7 |
10,9 |
316 |
321 |
|
1х35, ок |
11,7 |
11,9 |
410 |
416 |
|
1х50, ок |
13,1 |
13,3 |
540 |
546 |
|
2х6, ок, (N) |
11,8 |
13,0 |
257 |
294 |
|
2х10, ок, (N) |
14,1 |
14,5 |
391 |
405 |
|
2х16, ок, (N) |
17,9 |
18,3 |
640 |
659 |
|
2х25, ок, (N) |
21,0 |
21,4 |
918 |
940 |
|
2х35, ок, (N) |
22,9 |
23,3 |
1164 |
1188 |
|
2х50, ок, (N) |
26,0 |
26,4 |
1529 |
1556 |
|
3х6, ок |
12,4 |
13,7 |
316 |
358 |
|
3х10, ок |
14,9 |
15,4 |
488 |
504 |
|
3х16, ок |
18,9 |
19,3 |
790 |
811 |
|
3х25, ок |
22,1 |
22,5 |
1149 |
1173 |
|
3х35, ок |
24,4 |
24,8 |
1488 |
1515 |
|
3х50, ок |
27,5 |
28,0 |
1948 |
1978 |
|
4х6, ок, (N) |
13,4 |
14,9 |
393 |
445 |
|
4х10, ок, (N) |
16,3 |
16,8 |
613 |
633 |
|
4х16, ок, (N) |
20,5 |
21,0 |
976 |
1001 |
|
4х25, ок, (N) |
24,3 |
24,8 |
1442 |
1471 |
|
4х35, ок, (N) |
26,7 |
27,2 |
1869 |
1902 |
|
4х50, ок, (N) |
30,2 |
30,6 |
2453 |
2489 |
|
5х6, ок, (N, PE) |
14,6 |
16,2 |
489 |
552 |
|
5х10, ок, (N, PE) |
17,8 |
18,4 |
770 |
795 |
|
5х16, ок, (N, PE) |
22,3 |
22,8 |
1173 |
1215 |
|
5х25, ок, (N, PE) |
26,5 |
27,1 |
1750 |
1799 |
|
5х35, ок, (N, PE) |
29,2 |
29,7 |
2276 |
2314 |
|
5х50, ок, (N, PE) |
33,5 |
34,4 |
3040 |
3118 |
|
3х25ок+1х16ок, (N) |
24,1 |
24,6 |
1367 |
1396 |
|
3х35ок+1х16ок, (N) |
25,8 |
26,3 |
1677 |
1707 |
|
3х50ок+1х25ок, (N) |
29,2 |
29,6 |
2220 |
2254 |
|
1х16, мк |
7,5 |
10,2 |
234 |
239 |
|
1х25, мк |
8,3 |
11,8 |
341 |
347 |
|
1х35, мк |
9,4 |
12,8 |
437 |
443 |
|
1х50, мк |
10,9 |
14,7 |
592 |
599 |
|
1х70, мк |
15,8 |
782 |
||
|
1х95, мк |
17,9 |
1051 |
||
|
1х120, мк |
19,6 |
1281 |
||
|
1х150, мк |
21,5 |
1565 |
||
|
1х185, мк |
23,4 |
1939 |
||
|
1х240, мк |
27,2 |
2538 |
||
|
1х300, мк |
29,7 |
3124 |
||
|
2х16, мк, (N) |
18,4 |
18,8 |
659 |
678 |
|
2х25, мк, (N) |
21,6 |
22,0 |
952 |
974 |
|
2х35, мк, (N) |
23,6 |
24,4 |
1201 |
1250 |
|
2х50, мк, (N) |
27,8 |
28,2 |
1660 |
1689 |
|
3х16, мк |
19,4 |
19,8 |
810 |
832 |
|
3х25, мк |
22,8 |
23,2 |
1186 |
1211 |
|
3х35, мк |
25,4 |
25,8 |
1540 |
1568 |
|
3х50, мк |
29,4 |
29,9 |
2097 |
2130 |
|
4х16, мк, (N) |
21,0 |
21,5 |
999 |
1025 |
|
4х25, мк, (N) |
25,3 |
25,8 |
1498 |
1529 |
|
4х35, мк, (N) |
27,7 |
28,2 |
1930 |
1963 |
|
4х50, мк, (N) |
32,7 |
33,2 |
2677 |
2717 |
|
5х16, мк, (N, PE) |
22,9 |
23,4 |
1212 |
1690 |
|
5х25, мк, (N, PE) |
27,6 |
28,1 |
1830 |
2380 |
|
5х35, мк, (N, PE) |
30,3 |
30,8 |
2363 |
2300 |
|
5х50, мк, (N, PE) |
36,2 |
36,8 |
3309 |
3223 |
|
3х50, мс |
26,9 |
27,1 |
1904 |
1929 |
|
3х70, мс |
* |
30,0 |
* |
2556 |
|
3х95, мс |
* |
34,0 |
* |
3417 |
|
3х120, мс |
* |
36,9 |
* |
4185 |
|
3х150, мс |
* |
40,2 |
* |
5127 |
|
3х185, мс |
* |
44,1 |
* |
6276 |
|
3х240, мс |
* |
49,3 |
* |
8007 |
|
4х50, мс, (N) |
30,1 |
30,3 |
2465 |
2497 |
|
4х70, мс, (N) |
* |
34,0 |
* |
3372 |
|
4х95, мс, (N) |
* |
38,5 |
* |
4517 |
|
4х120, мс, (N) |
* |
41,5 |
* |
5487 |
|
4х150, мс, (N) |
* |
46,0 |
* |
6842 |
|
4х185, мс, (N) |
* |
50,0 |
* |
8319 |
|
4х240, мс, (N) |
* |
56,3 |
* |
10662 |
|
5х50, мс, (N, PE) |
33,6 |
33,8 |
3106 |
3130 |
|
5х70, мс, (N, PE) |
* |
37,9 |
* |
4220 |
|
5х95, мс, (N, PE) |
* |
42,6 |
* |
5579 |
|
5х120, мс, (N, PE) |
* |
46,7 |
* |
6881 |
|
5х150, мс, (N, PE) |
* |
50,9 |
* |
8443 |
|
5х185, мс, (N, PE) |
* |
56,1 |
* |
10369 |
|
5х240, мс, (N, PE) |
* |
62,4 |
* |
13157 |
|
3х70мс+1х35мс, (N) |
* |
33,0 |
* |
3005 |
|
3х95мс+1х50мс, (N) |
* |
37,4 |
* |
4047 |
|
3х120мс+1х70мс, (N) |
* |
40,4 |
* |
4982 |
|
3х150мс+1х70мс, (N) |
* |
43,9 |
* |
5978 |
|
3х185мс+1х95мс, (N) |
* |
48,3 |
* |
7392 |
|
3х240мс+1х120мс, (N) |
* |
53,5 |
* |
9334 |
|
2х50, мс, (N) |
* |
23,4 |
* |
1356 |
|
2х70, мс, (N) |
* |
25,8 |
* |
1797 |
|
2х95, мс, (N) |
* |
28,7 |
* |
2381 |
|
2х120, мс, (N) |
* |
30,7 |
* |
2851 |
|
2х150, мс, (N) |
* |
33,6 |
* |
3528 |
|
2х185, мс, (N) |
* |
36,6 |
* |
4303 |
|
2х240, мс, (N) |
* |
40,5 |
* |
5440 |
Type of climatic category acc. to GOST 15150: XL, placement category 1-5.
Cable grades are flame retardant at bunched laying.
Smoke emission at burning and smouldering of cables not decrease light transmission in test chamber more than 50%.
Value of equivalent toxicity index of burning cables not more 40 g/m3 Range of operating temperatures: from -500C up to +500C, for cables in “XL” application from - 600C up to +500C.
Relative atmosphere humidity at temperature up to +350C: up to 98%
Cable laying and assembly without preheating at temperature not less: -25 0C.
Admissible force at cable tension on the tray should not exceed 50 N/mm2
Cable conductor continuous heating temperature at work: +700C.
Maximum allowable temperature of conductors heating at short current circuits: +1600C Short circuit duration should not exceed 5 sec.
Admissible heating of cable conductors in emergency state: not more +900C.
Operating period of cables in overload period should not exceed 8 hours per day and not more 1000 hours per life period.
Maximum temperature of electric cable conductors without fire outbreak at short circuit – not more 3500C.
Minimum bending radius at laying not less:
- For single wires 10 diameters of cable
- For bending wires 7,5 diameters of cable
Life period: 30 years, according to stated transportation, storage, laying (assembly) and operation terms.
Guaranteed operating period: 5 years from the date of putting cable into operation, but not later than 6 months from the production date.